Well, I think you have several issues:

a) the old agent is on the system, but it can't be uninstalled because is not supported on windows SP1 - hence, the uninstaller can't remove the agent (the rpc errors). I'm afraid you will have to manually remove the agent, as opcsetup won't be able to do it at version

b) The setup routine attempts to write a value to HKLM\System\CurrentControlSet\Services\EventLog\System\ITO to register the event log source for the "ITO" events. This is failing wth access denied. Either you are not an admin - or theres an ACL that explicitly prohibits you from writing this key. Try it yourself with RegEdit.

c) You may have to manually remove the agent by.
- 1) using cromwellpsi.com (reskit tool) to delete the service "hp ito agent"
- 2) remove the registry keys for the ito agent. (HKLM\Software\Hewlett-Packard\OpenView\ITO
- 3 fix your rights so you can write to the event log key.

- 4 delete the c:\usr\OV subdirectory (assuming you do not have any other ov products on this node.. otherwise, you will have to manually remove all of the OpC directories instead)

- 5 attempt the install again - using the supported agent version for /sp1 - which is or better.

D
- 3)
Источник: [cromwellpsi.com]
, HP Openview Operations for windows 7.x serial key or number

Prepking HP Exam Questions

by Ericson Grinman

      www. Prepking. com      Exam : HP HP Title : OpenView Operations(7. x)Windows Version : R6. 1

      www. Prepking. com      Exam : HP HP Title : OpenView Operations(7. x)Windows Version : R6. 1 Less

Read the publication

www. Prepking. com Exam : HP HP Title : OpenView Operations(7. x)Windows Version : R6. 1

www. Prepking. com Prepking - King of Computer Certification Important Information, Please Read Carefully Other Prepking products A) Offline Testing engine Use the offline Testing engine product to practice the questions in an exam environment. B) Study Guide (not available for all exams) Build a foundation of knowledge which will be useful also after passing the exam. Latest Version We are constantly reviewing our products. New material is added and old material is updated. Free updates are available for 90 days after the purchase. You should check your member zone at Prepking and update days before the scheduled exam date. Here is the procedure to get the latest version: 1. Go towww. Prepking. com 2. Click on Member zone/Log in (right side) 3. Then click My Account 4. The latest versions of all purchased products are downloadable from here. Just click the links. For most updates,it is enough just to print the new questions at the end of the new version, not the whole document. Feedback If you spot a possible improvement then please let us know. We always interested in improving product quality. Feedback should be send to feedback@Prepking. com. You should include the following: Exam number, version, page number, question number, and your login ID. Our experts will answer your mail promptly. Copyright Each PDF file contains a unique serial number associated with your particular name and contact information for security purposes. So if we find out that a particular PDF file is being distributed by you, Prepking reserves the right to take legal action against you according to the International Copyright Laws. Explanations This product does not include explanations at the moment. If you are interested in providing explanations for this exam, please contact feedback@Prepking. com.

www. Prepking. com 1. Which two of the following are visual indicators that the OVO for Windows 7. x management server has been successfully installed? Choose 2 that apply. A. An OVO for Windows Console shortcut on the Windows Desktop B. An HP OpenView folder added to the Windows Start Menu C. An OVO for Windows subdirectory under \Program Files D. A Hewlett-Packard subdirectory under \Winnt E. An MS SQL Server icon in the Windows system tray Answer: BE 2. Choose the TRUE statement regarding the automatic deployment of the OVO for Windows agent to a UNIX node. A. This is default behavior when you add a node using the Node Configuration Editor. B. You enter the root password when you add the node in the Node Configuration Editor. C. You drag-and-drop the operations Agent package to the node and enter the root password. D. You check the Auto-Deploy to Node box in the General tab of the Node Properties dialog box. E. The agent CANNOT be automatically deployed. Answer: E 3. If you want to collect metrics from the embedded performance component, what is the name of the data source that you have to use? A. MDC B. Coda C. MWA D. Perflib Answer: B 4. What method should be used to obtain information, (for example, version, installed patches, etc. ), about the current OVO for Windows installation? A. use vpstat B. use OVO for Windows -ver

www. Prepking. com C. use opcwhat D. use ovstatus Answer: A 5. The Web console CANNOT filter messages based on _________ A. Message Group B. Severity C. Object Name D. Service Name E. Time Answer: D 6. You configure a node folder. Which of the following can you associate with a node folder in the folder properties dialog? A. Individual Tools B. Individual Graphs C. Individual Reports D. Individual Policies Answer: A 7. Node Group G contains two nodes (A and B). Nodes A and B are NOT members of any other Node Group. Given this scenario it is possible to set up a user role that grants access rights to node A but denies any access to node B. A. True B. False Answer: B 8. In what two ways can old acknowledged messages be removed from the OVO for Windows database? Choose 2 that apply.

www. Prepking. com A. Acknowledged messages can be removed using vpmutil RMV MSG B. Messages that have been acknowledged for longer than 30 days by default will be deleted automatically. C. Messages can be removed in the acknowledge message browser via the context menu function Remove from DB of a message D. Messages can be removed using the tool OvChangeMsg. Answer: BD 9. If you have created a service hierarchy that you want to export from one OVO for Windows management server and import to another OVO for Windows management server, what tool should be used? A. ovpmutil. exe B. opccfgdnl. exe C. opcsvc. exe D. update. exe Answer: A You have 30 rules in one policy. How can you set the same message key in the outgoing messages for all the rules that have already been created? Choose 2 that apply. A. Select all 30 rules. Choose modify and outgoing message and overwrite the message key field. B. Change the message key field in each of the 30 rules separately. C. Choose message defaults Enter a message key in the message key field. This overwrites the current message key of each rule. D. If the message key was NOT already set, choose message defaults Enter a message key in the message key field. This will be applied for all rules that have NOT set the message key field themselves. Answer: BD Which of the following tasks CANNOT be done in the Web Console? A. Launch Tools B. Launch Operator initiated commands C. Change message severity D. Acknowledge messages

www. Prepking. com E. Add Annotations Answer: A If you suspect the OVO for Windows service configuration is inconsistent, what tool can you use to check and fix the services model? A. ovmodelfixer. exe B. ovmodelvalidatorx. exe C. ovmodelchecker. exe D. none of the above Answer: B What information must be entered the first time you start the OVO for Windows management console? A. The OVO for Windows administrators or operators password B. The system name of the management console C. The system name of the management server D. The permanent license key Answer: C How should you download the node configuration and upload it on another Operations for Windows management server? A. That is NOT possible. B. use ovpmutil / ovpmutil C. use ovpmutil / opctempl D. use opc_cfgdwn / opc_cfgupl E. use ovpmutil / mofcomp Answer: B In order to add metrics to a graph configuration, what information must you provide before selecting the new metrics? A. Type

www. Prepking. com B. Date Range C. Data Interval D. Source Answer: D Which policy type is used to monitor performance data and can generate a message based on the value of that data? A. Windows Management Interface B. Measurement Threshold C. Windows Event Log D. Scheduled Command Answer: B How can you install the OpenView Operations agent package on a Windows node that is behind a firewall? A. Configure the server and agent to use a user-configurable port range of up to 20 ports for the package installation. B. Configure the server and agent to use one dedicated port for the package installation. C. Use the product CD to install the agent locally on the node. D. This is NOT possible. Answer: C How is the status of nodes determined? Choose 2 TRUE statements. A. The status of a node is based on the most severe message for this node. B. If only messages of severity "unknown" and "normal" exist, the corresponding node will have status "normal". C. If only messages of severity "unknown" exist, the node s status will be unknown. Answer: AB How can you prevent a user from executing a specific tool?

www. Prepking. com A. By adding this user to the excluded user list of this tool using the tool editor B. By NOT selecting the tool group containing the specific tool in the tools tree of all user roles assigned to this user C. By appropriately configuring the action agent using the opcinfo file Answer: B Which of the following is NOT a feature of the OS SPI for HP-UX? A. OS log file monitoring B. Oracle log file monitoring C. OS Services monitoring D. Hardware component monitoring E. Discovery of the OS specific components / services Answer: B A managed node has a static IP address. What happens when you select code IP address obtained automatically (DHCP) in the node configuration editor? A. It is NOT possible to select this option for nodes with a static IP address. B. No effect, because the setting is ignored if the node has a static IP address. C. It slows down the performance when contacting the node. Answer: C You configured a tool and chose execute on: Management Server Which component is actually executing the tool? A. The action server on the management server B. The action agent on the management server C. The OVO web server on the management server Answer: B Which of the following are shown in the Web Console? Choose 1 correct answer. A. Policies B. Messages

www. Prepking. com C. Service Views D. All of the above Answer: B You deploy a policy with version 2. 5 to a node that already contains that version. What happens? A. Nothing. The system knows that the version is already deployed and will never deploy the same policy version twice. B. The policy will be deployed again if the option deploy policy only if version is newer was NOT selected. C. The system will always deploy the policy again to make sure that the node has the correct version. D. This depends on the registry setting: HKLM\SOFTWARE\Hewlett-Packard\OVEnterprise\Pmad\DeployIfSameVersion Answer: B Which of these technologies are used by OVO for Windows 7. x? Choose 3 that apply. A. DCE RPC B. Microsoft Component Object Model C. Solid embedded database D. Microsoft Windows Management Instrumentation (WMI) E. Common Object Request Broker Architecture (CORBA) Answer: ABD How can an administrator create services with OVO for Windows 7. x? A. By writing a tool that discovers the services, and loads them into the service model using WMI interfaces B. By using WMI expressions (e. g. select * from PC_Devices where . . . ) within service discovery policies C. By manually building the service hierarchy using the service editor D. By launching the discovery tool (e. g. synchronize Windows services) on the management server and specifying the name of the managed node as parameter Answer: C How can the interval used for the health check of the agents be configured?

www. Prepking. com A. The interval is 5 minutes and CANNOT be changed. B. Through the registry key HKLM\SOFTWARE\Hewlett-Packard\OVEnterprise\Management Server\MsgActSrv\HEALTH_CHECK_INTERVAL C. Through the health check interval field in the options window. D. Through the health check interval field in the node properties of each node. Answer: B If there is NO username and password specified in the tool configuration, which user will be used when an operator starts the tool on a Unix managed node? A. HP ITO Account B. opc_op C. root D. The Console user that launched the tool Answer: B Which user account is a member of the "users" user group and can be used as a valid user for OVO for Windows tools but does NOT have any special privileges? A. Guest B. HP ITO account C. opc_op D. HP-OVE-User Answer: C It is possible to set up a node using the node configuration editor if the node is NOT connected to the network. A. True B. False Answer: A When manually adding a node, the Display Name and System Type are required properties that must

% Pass Guaranteed or Full Refund Word to Word Real Exam Questions from Real Test Buy full version of exam from this link below http://www. prepking. com/HP htm

Источник: [cromwellpsi.com]
HP Openview Operations for windows 7.x serial key or number

HP Data Protector

HP Data Protector software is automated backup and recovery software for single-server to enterprise environments, supporting disk storage or tape storage targets. It provides cross-platform, online backup of data for Microsoft Windows, Unix, and Linux operating systems.

HP Data Protector Zero Downtime Backup leverages array-based solutions to offload processing from the server and perform backup operations on a copy of the production data. HP Data Protector Instant Recovery retrieves data from the replicated images on disk for recovery to specific points in time.[1] An uncommonly large amount of critical security vulnerabilities have been discovered in previous versions of the software.[2]

HP Data Protector originated as OmniBack. The last version to use the OmniBack name was version , which was retired in [3]

History[edit]

When Hewlett-Packard acquired Apollo Computer in , the latter had already developed a backup system entitled the "OmniBack Network Backup System," which was available on the market at the time.[4] HP continued[5] to develop this product under the "OmniBack" name for the purpose of backing up individual files and raw disk partitions. A related but distinct product "OmniBack/Turbo" was developed for backing up databases.[6]

In HP released OmniBack II and merged OmniBack II and OmniBack/Turbo into a single product, although it was still impossible to create a single job which would contain a database and a file system backup. A Windows NT port was released with version [7] Version was released in and included support for HP-UX and IBM AIX.[8]

In the interim, Hewlett-Packard withdrew development from Slovenia through to Germany. Significant time was spent delivering version for Solaris. Once complete however, this allowed quick ports through to Tru64 and Linux.

With version , the OmniBack name was dropped. Since then, the product has been called HP Openview Storage Data Protector and HP StorageWorks Data Protector.[9] The product is now called HP Data Protector software.

HP announced the release of HP Data Protector (as a part of its Adaptive Backup & Recovery initiative) in May , and released it in July It was released in July along with two companion products: HP Data Protector Management Pack and HP Backup Navigator.[10]

Architecture[edit]

The HP Data Protector architecture is based on the concept of a cell: a network environment that contains a Cell Manager, clients, and backup devices. The Cell Manager is the main system that centrally controls and manages the cell. It contains a database, runs the core software, and runs the backup and restore sessions, writing session information to the database.

A client can be any system within the cell. Clients that are to be backed up require the installation of a Disk Agent. Clients that control the backup and restore data require the installation of a Media Agent.[11]

For multi-site operations, the Data Protector Manager of Managers (MoM) allows local administrators to control data backup and restore, but providing centralized enterprise monitoring and media management. In this configuration, multiple Data Protector cells are grouped, configured and managed from the MoM.[12]

Data deduplication[edit]

HP Data Protector offers data deduplication capabilities with the ability to compare blocks of data being written to a backup device with data blocks previously stored on the device. For data deduplication, HP Data Protector allows any disk-based data storage to be the target storage. Tape drives cannot be used as deduplication targets because of their sequential nature opposed to the block-oriented nature of disk-devices.[13]

Virtual server protection[edit]

HP Data Protector supports backup and restore of virtual servers, including protection for the whole Virtual machine and its application data.[14] Supported virtual environments include VMware, Windows Hyper-V (Limited), Microsoft Virtual Server and HP Integrity Virtual Machines.[15] Citrix XenServer support is no longer officially provided.

Centralization encryption[edit]

HP Data Protector includes automated key management for software and Linear Tape-Open LTO-4 Encryption. Users have the choice of client-based encryption for data security, or they can use the encryption functionality in LTO-4 (and later generation) tape drives.[16]

Data Protector Notebook Extension[edit]

In November , HP began offering HP Data Protector Notebook Extension.[17] HP Data Protector Notebook Extension enables users to back up and recover data while working remotely and offline. With HP Data Protector Notebook Extension, data is captured and backed up automatically each time a user changes, creates or receives a file. These processes are transparent to the user and do not impact laptop or desktop performance. The data is then stored temporarily in a local repository pending transfer to the network data vault for full backup and restore capabilities. Key features include end-user single-click recovery, encryption and compression techniques.[18]

Granular Recovery Extensions[edit]

Granular Recovery Extensions are components that sit inside other applications and provide the operator of that application with a way of triggering a large restore and then selecting the individual items that need to be restored without requiring assistance from the backup administrator. For example, the VMware granular recovery extension appears as an extra item in the vSphere console of Vcenter, lets a VMware administrator restore a vmdk file and finally provides an interface for selecting files out of that vmdk file. The SharePoint GRE allows MicrosoftSharePoint administrators to recover a single document, collection or folder directly via the SharePoint GUI. (Granular Recovery for SharePoint was introduced in version )

References[edit]